Understanding Maximum Demand Ammeters: Types, Applications, and Why Eutroniks Leads the Way
In today’s energy-driven world, especially across the Middle East, monitoring peak electrical demand is crucial for efficiency, cost control, and system safety. As businesses aim to optimize load usage, avoid penalties, and maintain compliance with DEWA, ADDC, and other regulatory standards, Maximum Demand Ammeters (MDAs) have become an indispensable tool in the design of switchboards, generator panels, and energy management systems.
🔍 What is a Maximum Demand Ammeter?
A Maximum Demand Ammeter measures the highest average current drawn over a set period, typically 15 minutes. Unlike standard ammeters that provide real-time readings, MDAs capture and retain peak demand events, giving operators a critical understanding of their system’s load profile.
These meters feature:
- A thermal bimetallic movement to measure the mean RMS current
- A red slave pointer that locks onto the maximum recorded current
- A manual reset knob to reset the recorded peak
- Robust shock-absorbing design for industrial environments
At GoSwitchgear, we proudly supply Eutroniks Maximum Demand Meters, engineered specifically for industrial and commercial applications in the GCC region.
🧱 Types of Maximum Demand Ammeters: Mono vs. Bi-Structure
1. Mono-Structure Maximum Demand Ammeters (SQ Series)
A Mono-Structure MDA uses a single thermal bimetallic movement to measure and display the peak demand over the specified time period.

📸 Mono-Structure Image:
Applications:
- Basic transformer station monitoring
- LT feeder panels
- Solar pump control systems
- Sites that only require peak load recording, not instantaneous values
2. Bi-Structure Maximum Demand Ammeters (SIQ Series)
A Bi-Structure MDA cleverly combines two movements:

- Thermal Bimetallic: For maximum demand over time
- Moving Iron: For real-time RMS current reading
📸 Bi-Structure Image:
Applications:
- Generator control panels (real-time and peak monitoring)
- Data centers and UPS systems
- Critical process industries where both instantaneous and historical readings are necessary
- Energy management systems require redundancy
⚙️ Key Features of Eutroniks Maximum Demand Ammeters
Feature | Description |
---|---|
Resettable Slave Pointer | Holds peak reading until reset manually |
Thermal Time Delay | Default 15 minutes (optional 8 or 20 minutes) |
Instantaneous RMS Option (SIQ) | Real-time load monitoring |
Scale Interchangeability | Easy dial replacement without accuracy loss |
Durable and Rugged Design | Anti-vibration, high-temperature-resistant materials |
IP Protection Options | IP40 to IP65 available for harsh environments |
Certifications | CE, ROHS, TSE compliant |
Low Power Consumption | Ideal for long-term panel integration |
Both SQ and SIQ series are manufactured with high-grade polycarbonate housings, explosion-proof glass, and UV-printed dials ensuring a long, maintenance-free service life.
🏢 Where Are Maximum Demand Ammeters Used?
Across the Middle East, particularly in the UAE, Saudi Arabia, Oman, and Qatar, MDAs are vital components in:
Industry/Application | Purpose |
---|---|
Power Distribution Panels | Transformer protection, peak monitoring |
Industrial Manufacturing | Load profiling, machinery current monitoring |
Renewable Energy Systems | Solar and wind system demand logging |
Commercial Building Management | Prevent overbilling due to excess demand |
Oil and Gas Facilities | Real-time load awareness and historical peak tracking |
Public Utilities and Substations | Demand charge compliance and energy auditing |
The thermal inertia of the bimetal movement makes these meters ideal for indicating prolonged load surges, helping facilities avoid costly penalties and system failures.
Application | Recommended Type | Description |
---|---|---|
Transformer Load Monitoring | Mono / Bi | Avoid overload, log peak demand |
LT Feeder Panels | Mono | Basic current profiling |
Diesel Generator Panels | Bi | Real-time + thermal tracking |
Factories and Warehouses | Mono | Long-duration load tracking |
Data Centers | Bi | Real-time precision needed |
Solar Pump Control Panels | Mono | Seasonal peak logging |
Utility Substations | Bi | Demand-based billing compliance |
Switchboards with SCADA/EMS | Bi | Redundant analog feedback to digital systems |
🌟 Why Choose Eutroniks Maximum Demand Ammeters?
- Dual measurement capability (instantaneous + peak) in SIQ models
- Highly customizable: change dials, scales, and mounting options easily
- Field-proven durability for harsh industrial environments
- Designed for Middle Eastern conditions: temperature resistance, vibration proofing, and IP ratings available on request
- Trusted by major panel builders and energy management companies across the UAE and GCC
Whether you need to simply track peak demand or gain a complete view of real-time and historical loads, Eutroniks Maximum Demand Ammeters deliver unmatched reliability and precision.
🛒 Available Now at GoSwitchgear.com
Equip your panels with the best in load monitoring technology. At GoSwitchgear, we supply Eutroniks Maximum Demand Meters tailored for your project needs.
✅ Fast delivery across UAE, KSA, Oman, Qatar
✅ Technical support for sizing and configuration
✅ Competitive pricing for bulk orders and panel builders